04.06

Sensors are designed for liquid and loose media temperature measurement by immersion (sensor 04.01), and also solid surface temperature measurement by contact method (sensors 04.03 – 04.06).
Cable temperature-sensing elements of the first tolerance class are used in surface temperature sensor modifications 04.01–04.06.
Cable temperature-sensing elements are armoured with steel tubes 4-8 mm diameter.
Sensor pressing to the surface is equal to 5-15 H.

Technical characteristics

sensor tolerance class:  к1 for details see table 5 page 2-9

Individual corrections to temperature values should be obtained together with the secondary unit in compliance with MI 1607-87.
Note: surface temperature sensors can be supplied with HH506RA-type secondary units.  Uncertainty of measurement of these units is equal to ±(0,3+0,05%Т), where Т – measurable temperature value. The unit has two measuring channels. The unit operates on "krona" battery. The unit supports the following thermocouple types: K, J, T, E, R, S, N. The unit allows to store up to 1000 measured values. The unit can be connected to PC. Description see in "Enclosures" section.

Hot junction one, grounded

Temperature range

TC type

Operating temperature range, *С

Cable sheath and reinforcement material

CTK,
CTL

0 to 500

S10 – steel 12Cr18Ni10Т

Thermal response time *, t0,95, с: 2.5

thermal response time (t0,95) – period of time required for thermocouple response to temperature step change by thermocouple signal change, which corresponds to 95% of specified step change.

 

Execution options

Extension lead length  should be selected within the range: 500, 1000, 1250, 1600, 2000 mm.


Thermocouple
type

Design
modification

Tolerance
class

Hot
junction
number
and type

Reinforcement
material

Outer
armour
diameter
D, mm

Insertion
length, L, mm

modification

typical
version*

min

max

CTK,
CTL

04.01

-060, -260, -050, -250    for CTK;

-063 for CTL

c2

G

S10

8.0

320

1000

04.03

04.04

04.05

04.06

6.0, 8.0

* – see Appendix for modification (extension lead) description. A thermocouple clip can be installed at the end of extension lead at customer's request (see section 11).

Examples of product designation

CTхх  04.ХХ-ХХХ - к2 - G - S10 - D - L /  ,
where   –  extension lead length, D – reinforcement outer diameter.
CTK 04.05-062 - к2 - G - S10 - 8 - 500 / 1000  –  chromel-alumel temperature sensor, modification 04.05-062 with  extension lead in PTFE sheath, tolerance class 2, grounded junction (G), cable temperature-sensing element in steel armour (S10), reinforcement outer diameter 8 mm, probe length 500 mm, extension lead length 1000 mm. Contact surface based on heat-insulating tile.