04.04
04.04
Sensors are designed for liquid and  loose media temperature measurement by immersion (sensor 04.01), and also solid  surface temperature measurement by contact method (sensors 04.03 – 04.06). 
Cable temperature-sensing elements of the first tolerance class are  used in surface temperature sensor modifications 04.01–04.06.
Cable temperature-sensing elements are armoured  with steel tubes 4-8 mm diameter.
Sensor pressing to the surface is equal to  5-15 H.
sensor tolerance class: к1 for details see table 5 page 2-9
Individual corrections to temperature values should be  obtained together with the secondary unit in compliance with MI 1607-87.
Note: surface temperature sensors can be  supplied with HH506RA-type secondary units.   Uncertainty of measurement of these units is equal to ±(0,3+0,05%Т),  where Т – measurable temperature value. The unit has two measuring channels.  The unit operates on "krona" battery. The unit supports the following  thermocouple types: K, J, T, E, R, S, N. The unit allows to store up to 1000  measured values. The unit can be connected to PC. Description see in  "Enclosures" section.
Hot junction one, grounded
| TC type | Operating temperature range, *С | Cable sheath and reinforcement material | 
| CTK, | 0 to 500 | S10 – steel 12Cr18Ni10Т | 
Thermal response time *, t0,95, с: 12
* thermal response time (t0,95) – period of time required for thermocouple response to temperature step change by thermocouple signal change, which corresponds to 95% of specified step change.
Extension lead length should be selected within the range: 500, 1000, 1250, 1600, 2000 mm.
| Thermocouple type | Design | Tolerance  | Hot  | Reinforcement  | Outer  | Insertion  | ||
| modification | typical | min | max | |||||
| CTK, | 04.01 | -060, -260, -050, -250 for CTK; -063 for CTL | c2 | G | S10 | 8.0 | 320 | 1000 | 
| 04.03 | ||||||||
| 04.04 | ||||||||
| 04.05 | ||||||||
| 04.06 | 6.0, 8.0 | |||||||
* – see Appendix for modification (extension lead) description. A thermocouple clip can be installed at the end of extension lead at customer's request (see section 11).
CTхх   04.ХХ-ХХХ - к2 - G - S10 - D - L /  , 
where   –   extension lead length, D –  reinforcement outer diameter.
CTK 04.05-062 - к2 - G - S10  - 8 - 500 / 1000  –  chromel-alumel temperature sensor,  modification 04.05-062 with  extension  lead in PTFE sheath, tolerance class 2, grounded junction (G),  cable temperature-sensing element in steel armour (S10),  reinforcement outer diameter 8 mm, probe length 500 mm, extension lead length 1000 mm. Contact surface based on  heat-insulating tile.