These sensors are designed for temperature measurement in liquid and gaseous non-corrosive media, and also corrosive media that do not damage protective cover material. Sensors are recommended to be used together with UNKJ thermowell.
PRTD 101K and 102K thermometers are designed for cryogenic temperature measurement. PRTD 101H and 102H is an alternative to copper thermocouple for temperature measurement up to 200°С.
To provide guaranteed sensor-connector contact we recommend to install
CRTD (PRTD) 102 sensors without mounting elements, by means of mounting fitting UNKJ 038 or movable fitting UNKJ 031 (see "UNKJ units and components" section).
Sensors can be of explosion protection type 0ExiaIICT6 X or 1ExdIICT6 according to GOST 30852.10-2002. For further details see "Alternative designs & Ordering information" below.
Terminal heads can be equipped with measuring transmitters with  4-20 mА DC output signal according to GOST 26.011 and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol, and also cable glands for additional cable fastening, and metal hose fastening, if required.    

Technical characteristics

Connection diagram

2-wire

Tolerance class В, С(see item 9 at page 6-5)

3-wire

Tolerance class АА, А, В, С

4-wire

Vibration resistance GOST R 52931

group V3

Nominal (rated)
pressure

6.3 MPa

101,101Н,101К,103 modifications

1,0 МПаif equipped with UNKJ 031 fitting
6,3 МПаif equipped with UNKJ 041 fitting

modifications
102, 102Н, 102К

Seismic resistance MSK-64

grade 9 for unit installation up to 70 m above zero mark

Climatic category GOST 15150

UHL2Ambient temperature:

-60..+120ºС for general purpose products

-60..+85 ºС for Ex version with analogous signal

-55..+85ºС for products with unified output signal

Calibration

- GOST 8. 461-2009 without measuring transmitters;
- MP RT 2026-2013 – for sensors with installed measuring transmitters.

Reliability indicators

Group of operating
conditions

Probability of
failure-free
operation

Specified lifetime

Mean
lifetime

Guarantee
conditions

I

0.95 for 40 000 hours

5 years

10 years

5 years

II

0.95 for 16 000 hours

2 years

4 years (6 years)*

2 years

III

0.95 for 8 000 hours

1 year

2 years

1 year

* - Increased mean lifetime with 0,6 failure-free operation possibility for the given period.

Error limits

Measurement accuracy of sensors with 4-20 mА DC signal and/or digital signal via HART protocol 

Output
signal

Nominal
designation

Measurement
accuracy
limits

Output
signal

Nominal
designation**

Measurement
accuracy
limits

4-20mА

AA3T25; А3T25

0,25 % · tn  or 0,5 °С

4-20mА
+
HART

AAxH25, AxH25

0,25 % · tn or 0,3 °С

B3T70

0,7 % · tn  or 1,0 °С

AxH10, BxH10

0,1 % · tn or 0,15 °С

A3T40

0,4 % · tn  or 0,5 °С

BxH70

0,7 % · tn or 1,0 °С

*   - tn thermocouple range should be multiplied by specified value in в %. Select higher value.
**  - «х» means number of wires in resistance thermometer connection diagram, х=3 or 4. For example, АА4Н25 or B3H70.

Temperature range

TC type

Thermowell diameter, mm

Thermowell material

Modification

Group of    
operating  
conditions

Tolerance
class

Application
temperature, °С

Cal. int.

Mean lifetime

CRTD

10, 8, 6

S10

101,102, 103

II

A

– 50…+120

2 years

4 years

10

S13

B, C

– 50…+200

PRTD

10, 8, 6

S10

101Н,102Н

I

A, B, С

– 50…+200

5 years

10 years

II

AA

– 50…+150

2 years

4 years

III

– 50…+250

1 year

2 years

101К, 102К,

II

A, B, С

– 196…+200

2 years

4 years

10

S13

101,102, 103

I

– 50…+300

5 years

10 years

II

– 50…450

2 years

4 years

III

B, C

– 50…600

1 years

2 years

Response time:


Sensor response time depending on diameter, s

d = 6; 8

d = 10

16

20

Execution options

PRTD

 

Exi

101

 

А

21

P100

В

3

Н10

S10

8

L

/

l

 

G1/2

1

 

2

3

4

 

5

6

 

7

8

 

9

10

11

 

12

 

13

 

14

 

15

 

16

 

NN

Name

Code

Description

1

Sensor type

CRTD

Copper resistance temperature detector

PRTD

Platinum resistance temperature detector

2

Explosion protection

Not filled

general purpose electrical equipment

Exi

0ExiaIICT6 X, intrinsically safe circuit

Exd

1ExdIICT6, explosion-proof enclosure

3

Modification

101.102, 103, 111

see drafts and operating temperature

4

Version (see "operating temperature" table)

Not filled

Standard version from -50 to +600°С

К

Cryogenic version from -200 to +200°С

G

Low-temperature version from -50 to +200°С

5

Cable gland

0

standard cable gland of terminal head

А

for unarmoured cable in metal hose RZCH-15

В

for unarmoured cable in metal hose MRPI-15

C

for unarmoured cable in metal hose DN18

D

for unarmoured cable in metal hose DN20

E

for unarmoured cable in metal hose DN12

F

for pipe assembly, М20х1,5 internal thread

G

for pipe assembly, output external thread G1/2

H

for unarmoured cable, 6.5 - 14 mm diameter

I

for unarmoured cable, 3.2 - 8.7 mm diameter

J

for cable with internal/external sheath diameter: 6,1-11,7/9,5-15,9, single-line wire armoured cable

К

for cable with internal/external sheath diameter: 3,1-8.7/6,1-11,5, all armour types

L

for cable with internal/external sheath diameter: 6,5-14/12,5-20,9, all armour types

6

Sensor terminal
head (see "Alternative
designs" 
page 1-10)

10

plastic head

IP55

general purpose

15; 16; 17; 18; 19

aluminium head

IP66/IP68

1ExdIICT6 / 0ExiaIICT6 X

20; 22

aluminium head

IP65

general purpose

14; 21; 23; 24; 25; 26; 28; 29

aluminium head

IP66

0ExiaIICT6Х or general purpose

27

stainless steel

IP66

0ExiaIICT6Х or general purpose

7

Number of SE

Not filled

one element

2хPt100

two elements

8

Type of TC

50М, 100М, 50P, 100P, Pt100, Pt500, Pt1000

NSC according to GOST 6651-2009

9

Tolerance class

АА, А, В, С

Tolerance class according to GOST 6651-2009

10

Connection diagram

3, 4

3- and 4-wire connection diagram for class АА, А

2, 3, 4

2-, 3-, 4-wire connection diagram for class В, С

11

Output signal, measuring transmitter accuracy designation - see table 3 at page 6-3

Not filled

analogous signal (Ohm) according to NSC

T25; T25

For terminal
head ≥14

4-20 mА

for AA3 and A3

T40

for A3

T70

for B3

H10, H10

4-20 mА +HART

for А4, В4, А3, В3

individual
sensor graduation

H25, H25

for АА4, А4, АА3, А3

H70

for В3, В4

12

Cable outer sheath material

S10

steel 12Cr18Ni10T

S13

steel 10Cr17Ni3M2T

13

Outer diameter

6, 8

size (mm) on Customer's choice

S10

10

S10, S13

14

Probe length, L

50÷3150

probe length L to the working end, mm

15

Extension neck length ℓ.

Not filled

if equal to 120 mm or there are no mounting elements

30÷500

specify dimension in mm, oif 120 mm doesn't fit

16

Fitting standard size

Not filled

if  threaded fitting M20x1.5 or no fitting is used

Specify thread size

in other cases

 

Examples of product designation

CRTD 103–010 – 100М – В3 – S10 – 8 – 100

Product type

CRTD

Copper resistance temperature detector

Explosion protection

general purpose

Modification

103

with thrust ring

Cable gland

0

standard

Wring (terminal head code)

10

IP55

Type of TC

100М

 

Tolerance class

В

class B

Connection diagram

3

3 wire

Output signal (accuracy class)

analogous

Sheath material

S10

steel 12Cr18Ni10T

Working end diameter

8

mm

Probe length L

100

mm

Extension neck length ℓ

120 mm